message_icon
call_icon +91-11-42580058
RB-48i
abacus_5 abacus_5 abacus_5
RB-48i is a fusion of reliability nad performance. Its versatility improves productivity of modern labs through its robust design, intuitive software and hassle free operation.

Built-in incubator of 7 positions

Flexible

  • Programmed to analyse endpoint, fixed time and kinetic assays
  • Storage for 200 user programmable test methods and 10000 test results
  • Clog detection and prevention with automatic system cleaningCreate up to 10 customized test profiles

Economical

  • Low reagent consumption
  • High quality surface coating ensures long filter life
  • Extended lamp life

Robust

  • Low maintenance
  • Consistent and reliable results
  • Indian design and manufacturing

PHOTOMETRIC MODULE

  • Seven Narrowband Interference Filters
  • Filter Wavelengts:340, 405, 505, 546, 578, 630 and 670 nm (1 open position for optional filter)
  • IAD Process: Ensures long filter life
  • Wavelength Accuracy: ±2 nm
  • Silicon Photo Diode detector
  • Absorbance Range: 0.0-3.0 A
  • Resolution: 0.00001 Absorbance units
  • Photometric Drift: <5 mAbs/30min
  • CV: <1%

TEMPERATURE OF FLOW CELL/CUVETTE

  • 25°C, 30°C, 37°C
  • Temperature Stability: ±0.2°C

DISPLAY

  • 5.7 Inch LCD display screen
  • High Contrast Display

KEYBOARD

  • Tactile touch QWERTY keypad
  • Visual indication on keypad during aspiration

PRINTER

  • Internal 57mm thermal printer with full graphics printing

MEASURING MODULE

  • Dual mode (flow cell & cuvette)
  • High-quality Quartz flow cell for precise measurements
  • 30 µl Flow cell volume
  • Peltier-controlled reaction temperature

UNITS

  • 15 pre-defined measurement units.

REACTION VOLUME

  • Minimum aspiration volume - 30µl
  • Maximum aspiration volume – 5ml

DIMENSIONS

  • Length : 422mm ∙ Height : 176mm
  • Width : 324mm ∙ Weight : 6.5kg

ANALYSIS METHOD

  • Endpoint, Fixed time and Kinetic
  • Sample blanking and reagent blanking
  • Direct Absorbance measurement mode
  • Coagulation Mode (PT/APTT/TT)

TEST PROFILES

  • User defined 10 test profiles
  • 10 tests can be added in each profile

TEST CHANNELS

  • 48 dedicated assays
  • Direct access keys for dedicated assays
  • Open channel capability
  • 200 programmable channels

DATA MANAGEMENT

  • Storage of up to 10,000 test results
  • Stores 30 days QC for each assay
  • Reagent blank storage

REPORTS

  • Search by date, sample ID, or test name
  • Calibration reports, QC results

INTERNAL INCUBATOR

  • Position: 7
  • Temperature: 37°C

QC AND CALIBRATION

  • Daily and monthly QC with data archiving

INTERFACE

  • RS 232 Port
  • USB Port
  • PC Connectivity (optional)

POWER

  • Input Voltage Range: 88-264 VAC
  • Frequency Range: 47-63 Hz
  • Power consumption: 75 W max
Quick Links